Dialogic® Diva® SIPcontrol™ Configuration
35
Type of
number
(outbound):
This parameter determines the shortest format allowed in calls sent out
by this interface. You can modify this parameter only if you selected a
dialplan from the drop down menu. The following options are available:
Unchanged: The number type signaled on the received call request or
the type previously set via an inbound dialplan or address map will be
used unchanged for dialing.
International number: The number is always converted to an
international number, including country and area code.
National number: The number is converted to a national number
unless it is an international number with a different country code.
Extension: The number is reduced as much as possible. An internal
number is reduced to its extension only.
For more information about number formats, see Overview of How Call
Address are Processed.
This parameter determines if numbers in calls sent out by this interface
should be encoded as unknown numbers with national or international
prefix digits, or as national or international numbers with type flags.
ISDN
numbering
plan -
Default
Change this setting only if the PBX rejects calls from Diva SIPcontrol
despite the dialed number being correct. This might occur, for example,
if the signaled numbering plan is not supported.
Presentation
indicator -
Default
If no presentation is specified via address rewriting, this parameter
specifies the presentation indicator to set on the calling party number
for calls to ISDN. The presentation indicator determines whether the
calling party number is shown or hidden from the called user.
This default does not apply to PSTN-PSTN calls, unless the known
presentation indicator is explicitly removed via an address map.
Komentarze do niniejszej Instrukcji