73
oversized_SDUs
Total number of oversized SDU errors that have occurred.
4.5.10 ATM_MSG_STREAM_STATE - ATM Stream Status Indication
Synopsis
Primitive generated by ATM to advise management of changes to the stream state.
Format
MESSAGE HEADER
Field Name
Meaning
type
ATM_MSG_STREAM_STATE (0x026a)
id
Cell Stream ID
src
ATM_Task_ID
dst
Management Module ID
rsp_req
0
hclass
0
status
Stream state (see table below)
err_info
Timestamp
len
0
Description
Sent by the ATM module when a stream becomes active or inactive
Value
Mnemonic
State
1
CELL_STREAM_IN_SERVICE
Entered IN SERVICE state
2
CELL_STREAM_OUT_SERVICE
Entered OUT OF SERVICE state