Podsumowanie treści

Strona 1 - DSI SS7HD Network Interface

April 2012 05-2063-11 www.dialogic.com Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual

Strona 2 - Copyright and Legal Notice

2 Specification 10 A CompactPCI line interface board providing 16 T1/E1/J1 ports (provided by a companion Rear Transition Module). The number of signa

Strona 3 - Contents

4 Message Reference 100 Value Mnemonic id Description 0x34 S7E_TX_FAIL l2_llid Failed to send LSSU/FISU to driver. 0x35 S7E_HDR_ERR l2_llid No room to

Strona 4

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 101 Value Mnemonic id Description 0x68 MTP_FLUSH_FAIL link_id MTP3 fail

Strona 5 - Figures

4 Message Reference 102 Value Meaning 0x66 License validation failure 0x67 License appears corrupt 0x70 Message congestion towards board cleared 0x

Strona 6 - Revision History

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 103 4.5.3 MVD_MSG_CLK_IND - Clock Event Indication Synopsis Message is

Strona 7 - 1 Introduction

4 Message Reference 104 4.5.4 MVD_MSG_LIU_STATUS - LIU Status Indication Synopsis Message issued by the board to provide notification of changes in L

Strona 8 - 1 Introduction

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 105 Value Mnemonic State 26 LIUS_BER5_CLRD BER5 cleared 27 LIUS_BER3_OC

Strona 9 - 2 Specification

4 Message Reference 106 4.5.6 MGT_MSG_DIAG_IND - Management Diagnostic Indication Synopsis Message sent by a module to a management entity to convey

Strona 10 - Form Factor Products

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 107 4.6 Status Request Messages Status request messages can be used to

Strona 11 - 2.2 Dialogic

4 Message Reference 108 state The current state of the LIU. The following table shows the permitted values and their meanings. Value Description 0 OK

Strona 12 - 2.2.3 Physical Interfaces

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 109 4.6.2 LIU_MSG_R_STATS - LIU Read Statistics Request Synopsis Messa

Strona 13 - 2.2.6 Power Requirements

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 11 2.2 Dialogic® DSI SS7HDP Network Interface Board - PCI Form Factor

Strona 14 - 2 Specification

4 Message Reference 110 Typically, a managing application would be set up to periodically (for example, hourly or daily) read and reset the statistics

Strona 15 - 2.2.10 Reliability

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 111 prbs_status The status of Pseudo Random Bit Sequence (PRBS) indicat

Strona 16 - 2.3 Dialogic

4 Message Reference 112 Description This message is sent to the board to read the current clocking state. The user should always request a confirmatio

Strona 17 - 2.3.3 Physical Interfaces

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 113 Value Description 0 Configured as CT Bus slave, PLL not used 1 Reco

Strona 18 - • Frame format

4 Message Reference 114 4.6.4 MGT_MSG_R_BRDINFO - Read Board Info Request Synopsis Message used to request basic board information. The message can b

Strona 19 - 2.3.6 Visual Indicators

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 115 Parameters The MGT_MSG_R_BRDINFO message includes the following par

Strona 20 - 2.3.7 Power Requirements

4 Message Reference 116 esn Electronic serial number. lsn License serial number. This is the serial number of the fitted license button. dram_size DRA

Strona 21 - 2.3.10 Reliability

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 117 4.6.5 DVR_MSG_R_L1_STATS - Link Statistics Request Synopsis Retrie

Strona 22 - See Dialogic

4 Message Reference 118 duration Duration in tenths of a second since the statistic counters were last reset. abort_cnt The number of aborts received

Strona 23 - Express Form Factor Products

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 119 Appendix A. Protocol Configuration Using Discrete Messages This ap

Strona 24 - 2.4.3 Physical Interfaces

2 Specification 12 2.2.2 Host Interface DSI SS7HDP boards support the PCI operation modes given in Table 1. Table 1. PCI Operation Modes Supported by

Strona 25 - 2.4.6 Power Requirements

4 Message Reference 120 5. Build and send a Layer 1 Configuration Request (MGT_MSG_L1_CONFIG) to set up the physical configuration parameters for the

Strona 26 - 2.4.10 Reliability

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 121 Figure 3. Protocol Configuration Message Sequence Diagram CTSWXSSD_

Strona 27 - 2.5 License Buttons

4 Message Reference 122 A.2 Monitoring Configuration Using Individual Messages To configure the board for monitoring it using individual messages, pr

Strona 28

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 123 Glossary AIS Alarm Indication Signal (Blue alarm). config.txt A

Strona 29

4 Message Reference 124 MSU Message Signal Unit. A data unit that carries signaling information for call control, transaction processing, network man

Strona 30

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 125 SLS Signaling Link Selection field. A field in the MTP3 routing la

Strona 31 - 2.6 SNMP Support

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 13 • Line codes HDB3, AMI (ZCS), AMI, B8ZS • Connector type RJ-45 2.2

Strona 32

2 Specification 14  Dimensions Board Length 312 mm (12.283 inches) – excludes ISA Retainer Height 106.68 mm (4.20 inches) Packaged Length

Strona 33 - 3.3 Monitoring

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 15 • Country-Specific Approvals See the Global Product Approvals list

Strona 34 - 3.4 Using the CT Bus

2 Specification 16 2.3 Dialogic® DSI SS7HDC Network Interface Board - CompactPCI Form Factor Products DSI SS7HDC boards are high-density, high perfor

Strona 35 - 3.4.2 Switching Model

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 17 • SS7 protocols MTP2 runs on the board. MTP3, ISUP, TUP, SCCP, TCAP

Strona 36 - 3.4.3 Static Initialization

2 Specification 18 • Data rate — T1: 1544 kbits/s ± 50 ppm — E1: 2048 kbits/s ± 50 ppm • Frame format — T1: D4, ESF, and ESF-CRC6 — E1: E1 and E

Strona 37 - 3.4.4 Dynamic Operation

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 19 2.3.5 Protocol Resource Support When used in a signaling node, the

Strona 38

2 Copyright and Legal Notice Copyright © 2003-2012 Dialogic Inc. All Rights Reserved. You may not reproduce this document in whole or in part without

Strona 39 - 0x0001 to 0x001F

2 Specification 20 Table 3. Dialogic® DSI SS7HDC Network Interface Boards Port Status Indications Green Yellow Red Condition On Off Off Normal operati

Strona 40 - 0x0100 to 0x0120

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 21 • Humidity 5 to 85% non-condensing • Altitude 197 ft (60 m) below

Strona 41 - 3.5.1 Host Configuration

2 Specification 22 See Dialogic® Telecom Products Warranty Information at http://www.dialogic.com/warranties.

Strona 42 - 3.5.2 Timestamp Output

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 23 2.4 Dialogic® DSI SS7HDE Network Interface Board - PCI Express Form

Strona 43 - 3.6 Hot Swap Operation

2 Specification 24 2.4.3 Physical Interfaces The DSI SS7HDE board (SS7HDED4TEQ) supports the following physical interfaces: • Four T1/E1/J1 digital

Strona 44

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 25 2.4.5 Visual Indicators The DSI SS7HDE board (SS7HDPD4TEW) includes

Strona 45

2 Specification 26 — +5°C to +40°C • Storage temperature range — -20° C to +40° C • Humidity — 5 to 85% non-condensing • Altitude — 197 ft (60

Strona 46

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 27 2.5 License Buttons The DSI SS7HD code file supports different prot

Strona 47 - 4 Message Reference

2 Specification 28 Table 6. Relationship between License Button Codes, Run Modes and Protocol Modules Buttons Run Mode Run Mode Value Protocol Modul

Strona 48

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 29 2.5.2 Run Modes and Protocol Dimensions The combination of the run

Strona 49

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 3 Contents 1 Introduction ...

Strona 50

2 Specification 30 Table 7. Protocol Dimensioning Supported by V5.07 of the Code File Buttons Run Mode Run Mode Value Number of Links (LSL/HSL) Number

Strona 51

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 31 2.6 SNMP Support The Dialogic® Distributed Structured Management In

Strona 52

3 SS7HD Board Product Specific Configuration and Operation 32 3 SS7HD Board Product Specific Configuration and Operation Before attempting software c

Strona 53

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 33 As an alternative to using s7_mgt, users can build their own configu

Strona 54

3 SS7HD Board Product Specific Configuration and Operation 34 3.3.1 Configuration The user needs to set up the configuration for the T1/E1/J1 interfa

Strona 55

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 35 3.4.1 Termination of the CT Bus Dialogic® DSI SS7HDP Network Interf

Strona 56

3 SS7HD Board Product Specific Configuration and Operation 36 Figure 1. CT Bus Connections When a call clears, the application needs to initiate gene

Strona 57

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 37 LIU_SC_DRIVE 0 0 512 0xfffefffe * 30 E1 voice ccts on ts 1..15 &

Strona 58

3 SS7HD Board Product Specific Configuration and Operation 38 * Function to drive an SCbus / CT Bus timeslot * onto a timeslot on a PCM port: */ int l

Strona 59

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 39 An example of an s7_mgt configuration file to connect a signaling li

Strona 60

Contents 4 3.4.2 Switching Model ... 35 3.4.3 S

Strona 61

3 SS7HD Board Product Specific Configuration and Operation 40 Note: All 32 signaling links from board 1, signaling processor 0, are driven up to CT B

Strona 62

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 41 3.5 Received Message Timestamping When used with the board and moni

Strona 63

3 SS7HD Board Product Specific Configuration and Operation 42 MONITOR_LINK 0 0 0-0 0 1 0xef 7 0x01 0xff 4. Configure the s7_log utility to displa

Strona 64

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 43 3.6 Hot Swap Operation Hot Swap operation is supported on SS7HDP, S

Strona 65

3 SS7HD Board Product Specific Configuration and Operation 44 Hot replacement operation is handled by the ssdh module and device driver. This mode of

Strona 66 - Synopsis

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 45 #!/bin/sh if [ ! -d /lib/modules/`uname -r`/misc ]; then

Strona 67

3 SS7HD Board Product Specific Configuration and Operation 46 • The second message has the status code set to SSDSI_FAILURE (0x62). If geographic add

Strona 68

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 47 4 Message Reference 4.1 Overview This section describes the indivi

Strona 69

4 Message Reference 48 Message Type Mnemonic Description 0x0f1d MGT_MSG_NTP_SYNC Timestamping Resynchronization Indication 0x1213 Confirmation of SS

Strona 70

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 49 Message Type Mnemonic Description 0x5213 SS7_MSG_TRACE_MASK* Set Tra

Strona 71

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 5 Appendix A. Protocol Configuration Using Discrete Messages ...

Strona 72

4 Message Reference 50 Message Type Mnemonic Description 0x7e34 LIU_MSG_CONFIG LIU Configuration Request 0x7e35 LIU_MSG_CONTROL LIU Control Request 0x

Strona 73

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 51 Mnemonic Value Description SS7_SP0_TASK_ID † 0x81 Signaling Process

Strona 74

4 Message Reference 52 4.1.3 Message Status Summary The following table shows the valid responses when a response request (rsp_req) is requested in a

Strona 75

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 53 4.2 General Configuration Messages General configuration messages a

Strona 76

4 Message Reference 54 4.2.1 SSD_MSG_RESET - SSD Reset Request Synopsis Sets up ssd module run-time options at initialization time. Note: When using

Strona 77

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 55 4.2.2 SSD_MSG_RST_BOARD - Board Reset Request Synopsis Reset a sing

Strona 78

4 Message Reference 56 code_file Null terminated string giving the filename of the code file to be downloaded to the board. run_mode The protocols

Strona 79

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 57 Value Run Mode Protocols Selected to Run on the Board 13 TCAP-ISUP S

Strona 80

4 Message Reference 58 4.2.3 SSD_MSG_BOARD_INFO - Board Information Request Synopsis Retrieves information about an SS7HD board. Format MESSAGE HEAD

Strona 81

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 59 — 1: PCI address mode — 2: H.110 address mode — 3: ADDR switch ad

Strona 82

1 Introduction 6 Revision History Issue Date Description 11 April 2012 Re-structured manual. Configuration and installation details moved to DSI Soft

Strona 83

4 Message Reference 60 4.2.4 MGT_MSG_CONFIG0 - Board Configuration Request Synopsis Message sent to a board immediately after starting the code runni

Strona 84

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 61 Set to 3 when using an SS7HD board. A separate link layer configurat

Strona 85

4 Message Reference 62 — Bit 9 - in general configurations, this should be set to 0. In dual fault tolerant configurations, Board A must set bit 9 to

Strona 86 - Request

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 63 4.2.5 MGT_MSG_L1_CONFIG - Layer 1 Configuration Request Synopsis M

Strona 87

4 Message Reference 64 sp_id Signaling processor ID. This is the logical identifier of the signaling processor on the board that handles the link. Pos

Strona 88

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 65 Value Clocking serial port 0 Internal, using data rate 1 External s

Strona 89

4 Message Reference 66 Value Description 0xffffffff unstructured E1 HSL 0x01ffffff unstructured T1 HSL 0xfffffffe structured E1 HSL, 31 slots (1 to

Strona 90

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 67 4.2.7 MGT_MSG_NTP_CONFIG - Network Time Configuration Synopsis Conf

Strona 91

4 Message Reference 68 4.3 Hardware Control Messages Hardware control messages are used to control various hardware devices on the board including th

Strona 92

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 69 4.3.1 LIU_MSG_CONFIG - LIU Configuration Request Synopsis Message s

Strona 93

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 7 1 Introduction Dialogic® DSI SS7HD Network Interface Boards include

Strona 94 - Parameters

4 Message Reference 70 Parameters A description of the permitted parameter values are given below. When the board is initially configured, all the LIU

Strona 95 - 4.4 MTP Interface Messages

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 71 crc_mode The CRC mode. The following table shows the permitted value

Strona 96 - Signaling Unit Data

4 Message Reference 72 nfaw The 8-bit value to be used for any E1 non-frame alignment word bit positions that are not modified by other options. Norma

Strona 97

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 73 Value Description 1 Terminated; normal impedance presented on the li

Strona 98

4 Message Reference 74 Description This message is sent to the board to perform dynamic changes to the operation of the LIU. It allows the user to con

Strona 99

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 75 Value Description 0 Do not change diagnostic loopback mode 1 Disable

Strona 100 - 4 Message Reference

4 Message Reference 76 4.3.3 LIU_MSG_R_CONFIG - LIU Read Configuration Request Synopsis Message sent by the application to read back the current Line

Strona 101

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 77 4.3.4 LIU_MSG_R_CONTROL - LIU Read Control Request Synopsis Message

Strona 102

4 Message Reference 78 4.3.5 MVD_MSG_SC_DRIVE_LIU - LIU CT Bus Initialization Request Synopsis Sets up a static switch path through the board between

Strona 103

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 79 sc_channel The channel number of the first channel to be used on the

Strona 104

1 Introduction 8 • Dialogic® SS7HDC Regulatory Notices • Dialogic® SS7HDE Regulatory Notices • Dialogic® Distributed Signaling Interface Components

Strona 105 - Indication

4 Message Reference 80 4.3.6 MVD_MSG_SC_LISTEN - CT Bus Listen Request Synopsis Message sent to the board to establish a connection from the CT Bus t

Strona 106

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 81 liu_id The identifier of the T1/E1/J1 LIU in the range 0 to one less

Strona 107 - 4.6 Status Request Messages

4 Message Reference 82 Parameters The MVD_MSG_SC_FIXDATA message includes the following parameters: liu_id The identifier of the T1/E1/J1 Line Interfa

Strona 108

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 83 4.3.9 MVD_MSG_SC_CONNECT - CT Bus Connect Request Synopsis Message

Strona 109

4 Message Reference 84 Parameters The MVD_MSG_SC_CONNECT message can include different parameters depending on the mode. The following table depicts t

Strona 110

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 85 Value Meaning 1 Make a simplex connection from a timeslot on the CT

Strona 111

4 Message Reference 86 dest_slot The destination slot references the CT Bus timeslot to which a local stream timeslot can be connected or disconnected

Strona 112

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 87 Description This message is sent to the board in order to control th

Strona 113

4 Message Reference 88 4.3.11 MVD_MSG_CNFCLOCK - Configure Clock Request Synopsis Message sent to an SS7HD board to configure or reconfigure the cloc

Strona 114

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 89 Value Bus speed 0 No change 3 8.192 MHz clk_mode Determines the c

Strona 115

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 9 2 Specification This section provides information about: • Product

Strona 116

4 Message Reference 90 Value PLL clock source 7 NETREF 1 8 NETREF 2 (CompactPCI only) The PLL clock is used as the reference when acting as CT Bus Pr

Strona 117

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 91 Value NETREF_2 clock mode 1 Drive NETREF_2 using clock recovered fro

Strona 118

4 Message Reference 92 4.3.12 MVD_MSG_CLOCK_PRI - Configure Clock Priority Request Synopsis Message sent to an SS7HD board to configure the clock rec

Strona 119 - Messages

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 93 Parameters The MVD_MSG_CLOCK_PRI message includes the following para

Strona 120

4 Message Reference 94 Parameters The MVD_MSG_LED_CTRL message includes the following parameters: led_n_state Specifies the state of the user LED. The

Strona 121

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 95 4.4 MTP Interface Messages MTP interface messages allow signaling l

Strona 122

4 Message Reference 96 Signaling Unit Data The SU data in binary format, excluding the Flags and Checksum, commencing with the Backwards Sequence Numb

Strona 123 - Glossary

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 97 4.4.2 API_MSG_RX_INDT - Timestamped Incoming Signaling Unit Indicat

Strona 124

4 Message Reference 98 4.4.3 API_MSG_TX_REQ - MTP2 Transmission Request Synopsis Message issued to the board by MTP3, containing an SS7 Message Signa

Strona 125

Dialogic® DSI SS7HD Network Interface Boards Programmer's Manual Issue 11 99 4.5 Event Indication Messages Event indication messages are the mec