Dialogic DSI SS7MD Instrukcja Użytkownika Strona 125

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 191
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 124
125
Dialogic
®
DSI SS7MD Programmer’s Manual Issue 3
E1 interfaces have 32 timeslots numbered 0 to 31. Timeslot 0 is used for frame alignment and
timeslot 16 is generally used for signaling or is empty. Hence the normal configuration is to cross
connect timeslots 1 to 15 and 17 to 31 between the two ports on each signaling board by setting the
<ts_mask> value to 0xfffefffe.
T1/J1 interfaces have 24 timeslots, numbered 1 to 24. To cross connect all the timeslots on a T1
interface between the two PCM ports on a signaling board, the <ts_mask> value 0x1fffffe should be
used.
In duplex mode both PCM ports should have been previously configured under the same type of PCM
connector T1, E1 or J1.
<pattern>
For DSI SS7MD Boards, not applicable. Set to 0.