name fields in the PBX to get integration to work. If you do not use this (7434ND) station type and
instead opt to use the 8434 station type, then you will be required to configure the name field of each
subscriber’s phone set to make sure that it includes their extension number in the name field,
somewhere within the first 15 characters. Below is an example of what to change on all your
subscribers (change shown in red type) if you do not use the 7434ND station set type on the gateway
ports.
change station 585 Page 1 of 5
STATION
Extension: 585 Lock Messages? n
Type: 8434D Security Code: TN: 1
Port: 01A0511 Coverage Path 1: 20 COR: 1
Name: 585 Smith, John Coverage Path 2: COS: 1
Hunt-to Station:
STATION OPTIONS
Loss Group: 2 Personalized Ringing Pattern: 1
Data Module? n Message Lamp Ext: 585
Speakerphone: 2-way Mute Button Enabled? y
Display Language: english Expansion Module? n
MWI Considerations
The Avaya PBX requires that the same port be used to turn off an MWI that is turned on. Keep this in
mind when troubleshooting any MWI issues. Consider this requirement when performing a system cut-
over from another solution. Message indicators on subscriber phones that are already activated prior
to a cut-over will most likely not be able to be turned off by the gateway. These lights will need to be
manually cleared by the PBX administrator. For these same reasons, any ports of the gateway that are
not planned to be used should be marked as disabled in the port capabilities configuration area of the
gateway.
Przeglądanie stron 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 21 22

Komentarze do niniejszej Instrukcji

Brak uwag